Definitive edition of Electric hot-air generator !!
|
High pressure Hot-air generator KD series
|
* This is the electric hot-air generator that the high pressure multistage blower of hot-air circulation type is equipped.
* Hot-air circulation system can be adopted at the rapid removing water drying line by the nozzle. And, the our heat exchanger can be attached.
|
|

|
|
High efficiency multistage blower is epuipped. This is the energy saving of about in comparison with the conventional high pressure blower !!
・ Continuous use max. hot-air temp. 350゚C ・ Discharge pressure is more than 12kPa. ・ Inverter for the air volume is controlled is equipped. (Energy saving !) ・ Hot-air circulation of 160゚C can be correspond at all type. (Energy saving !) ・ Demi-filter and the input-output service terminal are equipped to the all type. ・ Each safety circuit is built. (High reliability thermocouple is adopted to the each safety circuit.) Remote controller and Direction change can support. |
< Difference of TSK honeycomb block heater and sheathed heater >
Specification
|
 KD-56H3 KD-82H3
|
Model
|
Type |
Power 50/60Hz |
Heater capacity |
Continuous use max. temp. |
Motor capacity |
Max. air volume (m3/min) |
Max. static presuure (kPa) |
|
Delivery |
KD-24H3 |
3200-3C-1.5HY-LB |
3-phase 200V plus minus 10% |
3kW |
350゚C |
1.5kW |
7.1 |
12.1 |
|
E |
3200-5C-1.5HY-LB |
5kW |
3200-7.5C-1.5HY-LB |
7.5kW |
KD-56H3 |
3200-9C-2.2HY-LB |
9kW |
2.2kW |
10.0 |
13.5 |
|
E |
3200-12.5C-2.2HY-LB |
12.5kW |
KD-72H3 |
3200-15C-3.7HY-LB |
15kW |
3.7kW |
18.0 |
13.5 |
|
F |
3200-20C-3.7HY-LB |
20kW |
KD-82H2 |
3200-20C-5.5HY-LB |
20kW |
5.5kW |
27.8 |
13.2 |
|
F |
3200-30C-5.5HY-LB |
30kW |
KD-82H3 |
3200-20C-7.5HY-LB |
20kW |
7.5kW |
28.5 |
18.4 |
|
F |
3200-30C-7.5HY-LB |
30kW |
KD-82H5 |
3200-320C-11HY-L |
30kW |
11kW |
24.0 |
24.0 |
Order |
F |
Delivery A : Immediate delivery - 3 weeks B : 1 - 3 weeks C : 2 weeks - 1 month D : 1 - 1.5 months E : 1.5 - 2 months F : 2 - 3 months * Please inquire the evident delivery because the delivery may fluctuate by situation. |
Main option
|
|
|
|
|
Remote controller
|
|
|
|
|

|
Hot-air generator cab be operated by the remote controller that was established to the separated place. |
|
|
|
|
|
|
Resisting pressure HEPA- filter
|
|
|
|
|

|
Clean air that the collection efficiency is more than 99.97% is discharged by setting at outlet side of the hot-air generator. |
|
|
|
|
|
|
Heat exchanger
|
|
|
|
|

|
Heat collection of more than 40% is possible by setting the heat exchanger at the drying of organic solvent and many moisture.
|
|
|